System
AC Split System
AC tune-up and full system diagnostic completed. Found several components requiring attention — capacitor reading low, contactor showing wear, and refrigerant slightly below optimal levels.
Diagnostic Results
Capacitor reading low at 3.2μF (spec: 5μF) — needs replacement to prevent compressor strain and potential failure
Contactor showing pitting and arc damage — recommend replacement before it fails and leaves you without cooling
Refrigerant 1.5 lbs low (R-410A) — needs recharge for optimal cooling efficiency and to protect compressor
All other components within normal operating range — electrical connections tight, airflow good, thermostat calibrated